Search!
Advanced Network Analysis and Energy Management The KAEL ENERGY-11-DIN-100A is designed to maximize energy efficiency for industrial plants and commercial buildings. With external 100A current transformer compatibility, it reports not only energy consumption but also detailed power parameters that determine network quality.
Comprehensive Measurement: Precisely measures all fundamental parameters including active/reactive power per phase (P1, P2, P3 / Q1, Q2, Q3), current, voltage, and frequency.
Pulse Output Support: Facilitates the transfer of energy consumption data to automation systems and management software via 2 energy pulse outputs.
High Current Capacity: Directly compatible with external 100A current transformers (1:1 ratio), ensuring fast installation without extra configuration.
Security and Usability: Features a password-protected menu to prevent unauthorized access and a backlit LED display for easy reading in dark panels.
| Özellik / Feature | Detay / Detail |
| Bağlantı Tipi / Connection Type | 3 Faz & 4 Tel (3P & 4W) |
| Aktif Güç / Active Power (P1, P2, P3) | Sınıf 1 (1 class) |
| Reaktif Güç / Reactive Power (Q1, Q2, Q3) | Sınıf 2 (2 class) |
| Güç Faktörü / Power Factor (PF1, PF2, PF3) | Yok (None) |
| İthal/İhraç Aktif Enerji / Imp-Exp Active Energy | Sınıf 1 (1 class) - kWh |
| İthal/İhraç Reaktif Enerji / Imp-Exp Reactive Energy | Sınıf 2 (2 class) - kVARh |
| Talep ve Tepe Değerler / Demand and Peak | Yok (None) |
| Enerji Pals Çıkışı / Energy Pulse Output | 2 Adet (2 pcs) |
| Haberleşme / Communication (RS485 Modbus) | Yok (None) |
| Şifre Koruması / Password Protection | Var (Available) |
| Çalışma Sıcaklığı / Operating Temp. | -5°C .... +50°C |
| Depolama Sıcaklığı / Storage Temp. | -20°C .... +70°C |
| Ekran Tipi / Display Type | LED Display |
| Akım Trafosu / Current Transformer | Harici 100A (External 100A) |
| Akım Trafo Oranı / CT Ratio | 1 |
| Gerilim Trafo Oranı / VT Ratio | 1 .... 4000 |
| Yardımcı Besleme / Auxiliary Supply | 230 Vac <4VA |
| Boyutlar / Dimensions | 105 x 90 x 59 mm |
| Koli Adedi / Box Quantity | 12 Adet (12 pcs) |
It precisely measures active and reactive powers for each phase individually (P1, P2, P3 and Q1, Q2, Q3) in three-phase systems. It provides data transmission to automation systems via 2 energy pulse outputs and features a password-protected menu structure to prevent unauthorized access. It is compatible with external 100A current transformers, allowing direct high-current measurement with a fixed transformer ratio of 1.
You can contact us to get information about Optimum Control products and more.